Digtal scales from Sartorius, Mettler, Ohaus, AND Weighing, Myweigh & more

digital scale lab balances

Scaleman.com is your source for
balances & scales at discount prices
Since 1995!

Skip to Main Content »

Sartorius has the ideal solution for this most demanding metrological task: the MSU2.7S-000-DF micro balance. The draft shield on the MSU2.7S-000-DF has been specially developed for weighing filters. Not only is it ergonomically for both left and right-handed users, it also meets the highest standards for cleanability – an essential feature when working with nano particles – thanks to stainless steel components that can be easily dismounted for cleaning.
The special draft shield design makes this model particularly flexible in use: it is perfect for weighing the 47-mm filters specified in the EPA regulation, and can also be used with optional weighing pans for 75-mm or even 90-mm filters. And it does more than shield samples from drafts: it also provides excellent shielding from electrostatic charges.
Sartorius MSU display monochrome graphic display and keys that feature positive click action and precise activation of functions. For users who prefer to combine classic key-operated control with the widest range of performance features.
MSU2.7S-000-DF filter balance allows users to measure particle emissions in diesel fuel in accordance with 40 CFR 86.1312-2007. Weighing filters up to 50mm diameter with the standard weigh pan or purchase the optional 75 and 90mm pan for larger filters.
MSU2.7S-000-DF filter balance offers a full resolution from 0.1ug to 2.1g, meaning no further adaptations are required to allow the balance to be used for this highly specialized application.
MSU2.7S000DF filter weighing balance is now being used by several of the world's leading automotive manufacturers, where it has been adapted for use with the customer's own software programs for data evaluation and storage. Emissions testing is important not only in the automobile industry but also in the petrochemical and oil industries, and the sartorius filter weighing balance is just as well suited to these applications. Moreover it can also be used in research and testing institutions in the field of environmental technology, or indeed anywhere that the emissions produced by combustion processes are closely scrutinized.
Additional application maybe for EPA Federal Reference Method(FRM) for measuring PM 2.5 are in the Federal Register (40 CFR part 50, Appendix L, section 8).
Stabilize readings within an ultra fast 10 seconds, for maximum time savings with each weighing operation. The location of a microbalance is critical since environmental conditions can dramatically affect the weighing performance. Many people call us shopping for a microbalance and their only interest is what is the cost of the microbalance forgetting they might need a [a href="http://scaleman.com/catalogsearch/result/?order=relevance&dir=desc&q=static+eliminator"]static eliminator[/a] and spend $1000's to change the location they planned on installing the microbalance. The higher the lab balance resolution or accuracy, the more care must be taken with environmental conditions. Installation is always best on the ground level on a concrete foundation since installing the micro-balance on upper floor levels are more prone to the possibility of floor vibrations due structural motion and pedestrian movements. If you can't install your microbalance on the ground level installing the micro balance in a corner outside wall is the next best location. Always try to stay away from the middle of the floor since this area bends the most. Also the higher floor levels the balance is located, the greater the building sway and even slight misalignment along the vertical to the center of the earth can introduce substantial weighing error. A high precision microbalance should always be installed in a low traffic area. Due to the expense of the micro balance it should be in a restricted area to lessen the chance of unauthorized people from touching or using the microbalance. Install a [a href="http://scaleman.com/catalogsearch/result/?order=relevance&dir=desc&q=ultra+microbalance"]ultra-micro[/a] and [a href="http://scaleman.com/balances/micro-balances.html"]micro balances[/a] in quiet, temperature and humidity controlled, draft-free location is of paramount importance. Finding a location in cleanroom can many times be challenging due to laminar air flow. So before even considering purchasing a high precision laboratory balance you should consider the area you want to install the microbalance since if your environment is not ideal you don't have a defective microbalance but a defective environment. You can read more about selecting a location of your[a href="http://weigh.net/scientech/factors.html#installation"] lab balance here[/a]. A solid balance table or marble slab is recommended to eliminate the surface the microbalance is installed on to prevent bending and any flexing. The weighing table should also be decoupled from the environment with an additional layer of shock-absorbing material such as rubber or cork to lessen sensitive to shock and vibrations. Wooden tables have some degree of flexure and typically unsuitable to attain repeatable consistent weighing results with a microbalance. Marble tables should not only have a marble top but also marble legs and these tables typically weigh several hundred pounds and cost well over $1000 and installation and freight will also be costly. Please consider these issues are additional costs and many times required for the microbalance to perform to the capabilities of the precision weighing instrument. Controlling temperature changes is the most critical environmental condition that you must control and has the most serious affect on the performance of your microbalance. Temperature effects of even a difference of 1°C can cause sensitivity and zero point to shift. Although some people might say zero point drift can be resolved by taring the microbalance sensitivity drift will introduce systematic error. Sensitivity drift for the Sartorius MSU2.7S000DF is stated at ± 1 ppm / K. " K " is parts per million per °C rise in temperature. So if the temperature changes by 1°C you can expect 1 microgram change. Since the MSU2.7 has readability to 0.1 µg just a 1°C temperature change will affect the microbalance by 10 divisions 1.0 µg. A temperature change of 2°C might not sound like a lot but if you placed a sample of 0.0000100 grams (a hundredth of a milligram) a difference of 2°C will affect the observed weight of 0.0000100 gram mass by up to 2 micro grams. So instead the the microbalance reading 0.0000100 grams it could display between 0.0000120 grams to 0.0000080 grams. That is a lot of error just over a temperature change of 2°C and the lighter the sample the more significant the error. Once you have an adequate environment installing the [a href="http://scaleman.com/balances/micro-balances.html"]microbalance[/a] isn't difficult, but for those customers wishing for professional installation it is available at an additional cost. Please call us at 978-521-7095 for current prices for these services, but the average cost is $425 in the lower 48 states of the USA plus travel and expenses. IQ/OQ testing is also available for an average cost of $875 plus travel and expenses. Low humidity conditions tend to promote static electricity and causes havocs with your weight readings. Air conditioning removes moisture from air and can be one of the culprits to your static issues. The purchase of an optional [a href="http://scaleman.com/weighing-scale-accessory-ad1683-static-eliminator.html"]AD1683 static eliminato[/a]r can greater reduce static problems. The Sartorius MSU2.7S000DF microbalance is made to order in Germany with a typical lead time of 6-8 weeks. To check availability give us a call for current delivery times. If this lead time is unacceptable we would recommend you consider the preconfigured [a href="http://scaleman.com/microgram-filter-balance.html"]MSA2.7S0TRDF[/a] which Sartorius tries to keep in stock. Purchasing a [a href="http://scaleman.com/balances/micro-balances.html"]micro balance[/a] is an extremely costly purchase and sometime even more expensive is creating the proper environment. If you have any technical questions or want to check availability give the balance experts at Precision Weighing Balances a call at 978-521-7095. Free shipping in the lower 48 states for the MSU2.7S000DF ultra microgram filter balance.
Move your mouse over image or click to enlarge

More Views

Sartorius filter balance MSU2.7S-000-DF

2.1 g x 0.1 ug

Sartorius
See other products by Sartorius

Availability: Usually ships in 2 months

MSRP: $33,040.00

YOU PAY: $29,736.00

You save $3,304.00

Useful Downloads
Download Manual
Download Brochure
Download Additional Material
You Tube
Correct Use & Handling of Microbalances
Filter weighing brochure
Sartorius Cubis ultra microbalance brochure

Quick Overview

Cubis Ultra-Micro Filter weighing Balance (2.1 grams x 0.1 micrograms) with Black & White Graphical display. Stainless steel manual draft shield for weighing filters with diameters of up to 50 mm/1.97 inches (75 mm & 90 mm optionally available)

MSRP: $33,040.00

YOU PAY: $29,736.00

You save $3,304.00
Add Items to Cart

Product Description

Sartorius has the ideal solution for this most demanding metrological task: the MSU2.7S-000-DF micro balance. The draft shield on the MSU2.7S-000-DF has been specially developed for weighing filters. Not only is it ergonomically for both left and right-handed users, it also meets the highest standards for cleanability – an essential feature when working with nano particles – thanks to stainless steel components that can be easily dismounted for cleaning.

The special draft shield design makes this model particularly flexible in use: it is perfect for weighing the 47-mm filters specified in the EPA regulation, and can also be used with optional weighing pans for 75-mm or even 90-mm filters. And it does more than shield samples from drafts: it also provides excellent shielding from electrostatic charges.

Sartorius MSU display monochrome graphic display and keys that feature positive click action and precise activation of functions. For users who prefer to combine classic key-operated control with the widest range of performance features.

MSU2.7S-000-DF filter balance allows users to measure particle emissions in diesel fuel in accordance with 40 CFR 86.1312-2007. Weighing filters up to 50mm diameter with the standard weigh pan or purchase the optional 75 and 90mm pan for larger filters.

MSU2.7S-000-DF filter balance offers a full resolution from 0.1ug to 2.1g, meaning no further adaptations are required to allow the balance to be used for this highly specialized application.

MSU2.7S000DF filter weighing balance is now being used by several of the world's leading automotive manufacturers, where it has been adapted for use with the customer's own software programs for data evaluation and storage. Emissions testing is important not only in the automobile industry but also in the petrochemical and oil industries, and the sartorius filter weighing balance is just as well suited to these applications. Moreover it can also be used in research and testing institutions in the field of environmental technology, or indeed anywhere that the emissions produced by combustion processes are closely scrutinized.

Additional application maybe for EPA Federal Reference Method(FRM) for measuring PM 2.5 are in the Federal Register (40 CFR part 50, Appendix L, section 8).

Stabilize readings within an ultra fast 10 seconds, for maximum time savings with each weighing operation.


The location of a microbalance is critical since environmental conditions can dramatically affect the weighing performance. Many people call us shopping for a microbalance and their only interest is what is the cost of the microbalance forgetting they might need a static eliminator and spend $1000's to change the location they planned on installing the microbalance. The higher the lab balance resolution or accuracy, the more care must be taken with environmental conditions.

Installation is always best on the ground level on a concrete foundation since installing the micro-balance on upper floor levels are more prone to the possibility of floor vibrations due structural motion and pedestrian movements. If you can't install your microbalance on the ground level installing the micro balance in a corner outside wall is the next best location. Always try to stay away from the middle of the floor since this area bends the most. Also the higher floor levels the balance is located, the greater the building sway and even slight misalignment along the vertical to the center of the earth can introduce substantial weighing error.

A high precision microbalance should always be installed in a low traffic area. Due to the expense of the micro balance it should be in a restricted area to lessen the chance of unauthorized people from touching or using the microbalance.

Install a ultra-micro and micro balances in quiet, temperature and humidity controlled, draft-free location is of paramount importance. Finding a location in cleanroom can many times be challenging due to laminar air flow. So before even considering purchasing a high precision laboratory balance you should consider the area you want to install the microbalance since if your environment is not ideal you don't have a defective microbalance but a defective environment. You can read more about selecting a location of your lab balance here.

A solid balance table or marble slab is recommended to eliminate the surface the microbalance is installed on to prevent bending and any flexing. The weighing table should also be decoupled from the environment with an additional layer of shock-absorbing material such as rubber or cork to lessen sensitive to shock and vibrations. Wooden tables have some degree of flexure and typically unsuitable to attain repeatable consistent weighing results with a microbalance. Marble tables should not only have a marble top but also marble legs and these tables typically weigh several hundred pounds and cost well over $1000 and installation and freight will also be costly. Please consider these issues are additional costs and many times required for the microbalance to perform to the capabilities of the precision weighing instrument.

Controlling temperature changes is the most critical environmental condition that you must control and has the most serious affect on the performance of your microbalance. Temperature effects of even a difference of 1°C can cause sensitivity and zero point to shift. Although some people might say zero point drift can be resolved by taring the microbalance sensitivity drift will introduce systematic error. Sensitivity drift for the Sartorius MSU2.7S000DF is stated at ± 1 ppm / K. " K " is parts per million per °C rise in temperature. So if the temperature changes by 1°C you can expect 1 microgram change. Since the MSU2.7 has readability to 0.1 µg just a 1°C temperature change will affect the microbalance by 10 divisions 1.0 µg. A temperature change of 2°C might not sound like a lot but if you placed a sample of 0.0000100 grams (a hundredth of a milligram) a difference of 2°C will affect the observed weight of 0.0000100 gram mass by up to 2 micro grams. So instead the the microbalance reading 0.0000100 grams it could display between 0.0000120 grams to 0.0000080 grams. That is a lot of error just over a temperature change of 2°C and the lighter the sample the more significant the error.

Once you have an adequate environment installing the microbalance isn't difficult, but for those customers wishing for professional installation it is available at an additional cost. Please call us at 978-521-7095 for current prices for these services, but the average cost is $425 in the lower 48 states of the USA plus travel and expenses. IQ/OQ testing is also available for an average cost of $875 plus travel and expenses.

Low humidity conditions tend to promote static electricity and causes havocs with your weight readings. Air conditioning removes moisture from air and can be one of the culprits to your static issues. The purchase of an optional AD1683 static eliminator can greater reduce static problems.

The Sartorius MSU2.7S000DF microbalance is made to order in Germany with a typical lead time of 6-8 weeks. To check availability give us a call for current delivery times. If this lead time is unacceptable we would recommend you consider the preconfigured MSA2.7S0TRDF which Sartorius tries to keep in stock.

Purchasing a micro balance is an extremely costly purchase and sometime even more expensive is creating the proper environment. If you have any technical questions or want to check availability give the balance experts at Precision Weighing Balances a call at 978-521-7095.

Free shipping in the lower 48 states for the MSU2.7S000DF ultra microgram filter balance.

 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.

Hot Buys!

Community Poll

What is your favorite balance ?
 
 
 
 
 
 
 
 
  Loading...
Featured Laboratory Balances:
600 g x 0.01 g $259.77
60 g x 0.1 mg $999.51