| Capacity x Readability (g) |
100 g x 0.0001 g (Menu code 1.7.1) |
| Capacity
x Readability (g) |
100 g x 0.0002 g (Menu code 1.7.2) |
| Capacity x Readability (ct) |
500
ct x 0.001 ct (Menu code 1.7.4) |
| Capacity
x Readability (lb) |
0.22085
lb x 0.00001 lb (Menu code 1.7.5) |
| Capacity x Readability (oz) |
3.53361
oz x 0.00001 oz (Menu code 1.7.6) |
| Capacity
x Readability (ozt) |
3.22074 ozt x 0.00001 ozt (Menu code 1.7.7) |
| Capacity
x Readability (GN) |
1545.955
GN x 0.005 GN (Menu code 1.7.11) |
| Capacity x Readability (dwt) |
64.4148 dwt x 0.0001 dwt (Menu code 1.7.12) |
| Capacity x Readability (mg) |
100176.2 mg x 0.2 mg (Menu code 1.7.13) |
Legal
for Trade
(NTEP approved) |
YES - CofC 05-099 Legal for Trade in gram & carat mode ONLY |
| NTEP Capacity x Readability (g) |
100 g x 0.001 g |
| NTEP Capacity x Readability (ct) |
500
ct x 0.01 ct |
Reproducibility (std deviation)
carats (ct)
grams (g) |
± 0.001 ct
± 0.0001 g |
Linearity
carats (ct)
gram (g) |
± 0.002 ct
± 0.0002 g |
| Scale
interval d |
0.0001
g |
| Verification scale interval e |
0.001 g |
| Response Time (average) |
3
seconds |
| Tare
Range |
FULL
to Capacity |
Selectable Weight Units
|
g, ct, lb, oz, ozt, tlh, tls, tlt, Gn, dwt, mg, parts/lb, tlc, mom, K,
tol, bat, and MS. In LFT mode the the GD503
weighs in Carat & Grams ONLY |
| Selectable Application Programs |
Mass unit conversion by toggling, tare memory, net total, weighing in
percent, counting, averaging. Counting
function not legal for trade |
| Display Update |
0.1 - 0.4 seconds depended upon filter level selected |
| Display |
LCD |
| Allowable Ambient Operating Temperature |
20° C to 35° C (68° F to 95° F)
85% RH or less |
Sensitivity
Drift
(10° - 30°C/50°F-86°F) |
± 2 ppm / °C |
| External Calibration |
100g INCLUDED |
| Pan Size |
ø90 mm / 3.5 in
(standard round pan) |
Draft Shield Chamber Height
(from pan to top of glass door) |
133 mm / 5.23 in |
Dimensions (entire balance)
W x D x H |
200
x 270 x 233 mm
7.9 x 10.6 x 9.2 in |
| Built-in RS-232 Interface |
YES
- RS-232 interface is standard but the RS-232
cable is optional |
| Weighing Below |
Not
Available. Common applications for weighing below the balance include
density determination. |
| AC Power Source |
AC
Adapter 120 VAC |
| Power Consumption |
Approx.
16VA (supplied by AC adapter) |
| Standard Equipment |
120V
AC Adapter, Dust Cover, Stainless steel weighing pan, 100g external
cal mass |
| Optional Accessories |
Printer, RS-232
cable, RS-232 to
USB converter kit, Rechargeable external battery pack, WinWedge data
transfer software |