Digtal scales from Sartorius, Mettler, Ohaus, AND Weighing, Myweigh & more

digital scale lab balances

Scaleman.com is your source for
balances & scales at discount prices
Since 1995!

Skip to Main Content »

FX300iN NTEP Legal For Trade class 2 scale by AND weighing offers 320g with one milligram readability. A&D has build an amazing low cost magnetic force restoration balance that performs lightening fast using their Super Hybrid Sensor technology. This patented weigh cell provides quick stabilization speed with accurate weighing result in 1 second resulting in better productivity. The compact size and small footprint is something no other competitor brand can offer. The vacuum fluorescent display enables easy-to-read weighing results even in poor lighting conditions. The FXiN Series comes standard with RS-232C interface for bi-directional communication with a PC, printer or other peripheral devices. When purchased with the optional[a href="http://scaleman.com/and-scale-printer-ad-8121b.html"] AD-8121B printer[/a] you'll be GLP/GMP/GCP/ISO Compliant. In accordance with GLP and LIMS regulations, the balance ID number and calibration data can be printed out using A&D AD-8121B or a PC The FX-iN meets EMC regulations and is immune to the effects of electromagnetic fields of up to 10V/m All FX-iN balances are backed with a 5 years manufacturer warranty making it the longest manufacturer warranty in the industry for a high quality lab balance. Many people haven't heard of A&D Weighing but they are the third largest manufacturer of laboratory balances and scales in the world. Corporate headquarters are based in Japan but US offices in California and Georgia. We understand purchasing a quality milligram balance is a major capital expense and if you have any questions give us a call and one of our weighing experts can discuss your weighing application and get you the most affordable balance for your weighing needs. Precision Weighing Balances has been selling lab balances online since 1995 and we know balances so well we've been hired by some of the most prestigious law firms in America as an expert witness. Sadly, most of the catalog companies and vendors online have never even turned on a balance and can't answer any questions about how the balance functions.
There is a lot of confusion when it comes to buying the FX-i NTEP digital balances and hopefully the video above will clear those issues up do you don't purchase the wrong balance.

In this video I will be using the [a href="http://scaleman.com/ntep-approved-fx300in-scale.html"]FX-300iN[/a] and what I will be covering is applicable to all the FX-iN models which includes the [a href="http://scaleman.com/ntep-approved-fx120in-scale.html"]FX120iN[/a]. [a href="http://scaleman.com/fx200in-ntep-approved-digital-scale.html"]FX200iN[/a], FX300iN, [a href="http://scaleman.com/digital-scale-ntep-approved-fx1200in.html"]FX1200iN[/a], [a href="http://scaleman.com/ntep-approved-fx2000in-scale.html"]FX2000iN[/a] and [a href="http://scaleman.com/ntep-approved-fx3000in-weighing-scale.html"]FX3000iN[/a]. So if you listened carefully you heard all the model numbers ended with the letter "N" which designate NTEP Approved or Legal for Trade for the AND FX-i Series. Many people really don't see any difference between the FX-300iN and the FX-300i, but there is. If you require a legal for trade weighing device especially for commercial weighing and you ordered the non-NTEP version you will have problems. As you can guess the FX-iN NTEP Approved models costs more than the FX-i Non-NTEP models.

If you are a pharmacy needing to meet the requirements for maintaining your pharmacy license you want to order the FX-300iN and not the FX-300i. The same goes for a Oregon marijuana dispensary you need the [a href="http://scaleman.com/ntep-approved-fx300in-scale.html"]FX-300iN[/a], while Colorado marijuana dispensaries as of March 2016 are allowed to use the [a href="http://scaleman.com/digital-scale-ntep-approved-fx1200in.html"]FX1200iN[/a], [a href="http://scaleman.com/ntep-approved-fx2000in-scale.html"]FX2000iN[/a] or [a href="http://scaleman.com/ntep-approved-fx3000in-weighing-scale.html"]FX3000iN[/a]. Eventually we think Colorado recreational cannabis dispensaries will follow Oregon's rules requiring the FX300iN since this model has a verification scale division of "e"=0.01g and "d"=0.001g.

So here are the differences. You receive the manual with a 1 page addendum explaining how to calibrate the balance along with a "sealing plate" and two(2) "sealing screws" and labeling above the display.

You will notice the sealing screw has a hole and this allows the Weights and Measures Inspector to place a wire through the hole and then crimp the wires together with a lead slug similar to how an electric or water meter was sealed to prevent people from tampering. Placing the wire through these screws prevents you from accessing the calibration switch to initialize the start of a new calibration.

Every balance should be calibrated prior to weighing and you should check with Weights and Measures if you can perform the calibration by purchasing your own optional calibration weight, if you have to hire a local licensed scale technician to perform the calibration or if the Weights and Measures Inspector will calibrate the scale when they inspect it and put the scale into service. You'll need to research this on your own and in some states it can cost you over $150 just for the inspection. Typically they will also place a State W&M Seal on the balance with an expiration date since scales typically they have to be verified and inspected for accuracy yearly.

You will see on the front of the balance above the display a label denoting the model number. This is where so much confusion occurs. The model is shown as FX-300i, then a circle with II inside of the circle meaning this is a Class 2 weighing device, CC 08-045 and the wording "The counting feature is not legal for trade". But wait I thought I ordered the FX-300iN yet the balance is labeled FX-300i.

What has happened is AND Weighing converts the FX-300i into the FX-300iN by changing the balance's internal software so it complies with NTEP requirements. Part of this is so the calibration can be locked out also so the last decimal place on the display is "boxed". They also place the sticker above the display identifying the CofC number and supply the two sealing screws & sealing plate. All these changes and A&D markets the product as the FX-300iN and charges more money.

Many marijuana dispensaries either already have a FX-iN balance and want to expand and order another balance or they visited a dispensary so they can figure out the equipment they need to start a store. Although looking at the digital balance's label is marked either FX-300i for Oregon or for dispensaries in Colorado FX-1200i you need to make sure you order the FX-300iN or FX-1200iN.
Move your mouse over image or click to enlarge

More Views

AND FX300iN NTEP approved class II scale

320 g x 0.001 g

AND
See other products by AND

Availability: In Stock

MSRP: $1,085.00

YOU PAY: $813.75


MFR won't let us advertise below $813.75.

Useful Downloads
Download Manual
Download Brochure
Download Additional Material
You Tube

Quick Overview

FX300iN class 2 legal for trade digital scale offers 320 gram maximum capacity with 0.001 g resolution. This scale meets the requirements of Minnesota Department of Commerce Weights & Measures scale requirements for weighing precious metals

MSRP: $1,085.00

YOU PAY: $813.75


MFR won't let us advertise below $813.75.
Add Items to Cart

Product Description

FX300iN NTEP Legal For Trade class 2 scale by AND weighing offers 320g with one milligram readability.

A&D has build an amazing low cost magnetic force restoration balance that performs lightening fast using their Super Hybrid Sensor technology. This patented weigh cell provides quick stabilization speed with accurate weighing result in 1 second resulting in better productivity. The compact size and small footprint is something no other competitor brand can offer.

The vacuum fluorescent display enables easy-to-read weighing results even in poor lighting conditions.

The FXiN Series comes standard with RS-232C interface for bi-directional communication with a PC, printer or other peripheral devices. When purchased with the optional AD-8121B printer you'll be GLP/GMP/GCP/ISO Compliant. In accordance with GLP and LIMS regulations, the balance ID number and calibration data can be printed out using A&D AD-8121B or a PC

The FX-iN meets EMC regulations and is immune to the effects of electromagnetic fields of up to 10V/m

All FX-iN balances are backed with a 5 years manufacturer warranty making it the longest manufacturer warranty in the industry for a high quality lab balance.

Many people haven't heard of A&D Weighing but they are the third largest manufacturer of laboratory balances and scales in the world. Corporate headquarters are based in Japan but US offices in California and Georgia.

We understand purchasing a quality milligram balance is a major capital expense and if you have any questions give us a call and one of our weighing experts can discuss your weighing application and get you the most affordable balance for your weighing needs. Precision Weighing Balances has been selling lab balances online since 1995 and we know balances so well we've been hired by some of the most prestigious law firms in America as an expert witness. Sadly, most of the catalog companies and vendors online have never even turned on a balance and can't answer any questions about how the balance functions.





There is a lot of confusion when it comes to buying the FX-i NTEP digital balances and hopefully the video above will clear those issues up do you don't purchase the wrong balance.

In this video I will be using the FX-300iN and what I will be covering is applicable to all the FX-iN models which includes the FX120iN. FX200iN, FX300iN, FX1200iN, FX2000iN and FX3000iN. So if you listened carefully you heard all the model numbers ended with the letter "N" which designate NTEP Approved or Legal for Trade for the AND FX-i Series. Many people really don't see any difference between the FX-300iN and the FX-300i, but there is. If you require a legal for trade weighing device especially for commercial weighing and you ordered the non-NTEP version you will have problems. As you can guess the FX-iN NTEP Approved models costs more than the FX-i Non-NTEP models.

If you are a pharmacy needing to meet the requirements for maintaining your pharmacy license you want to order the FX-300iN and not the FX-300i. The same goes for a Oregon marijuana dispensary you need the FX-300iN, while Colorado marijuana dispensaries as of March 2016 are allowed to use the FX1200iN, FX2000iN or FX3000iN. Eventually we think Colorado recreational cannabis dispensaries will follow Oregon's rules requiring the FX300iN since this model has a verification scale division of "e"=0.01g and "d"=0.001g.

So here are the differences. You receive the manual with a 1 page addendum explaining how to calibrate the balance along with a "sealing plate" and two(2) "sealing screws" and labeling above the display.

You will notice the sealing screw has a hole and this allows the Weights and Measures Inspector to place a wire through the hole and then crimp the wires together with a lead slug similar to how an electric or water meter was sealed to prevent people from tampering. Placing the wire through these screws prevents you from accessing the calibration switch to initialize the start of a new calibration.

Every balance should be calibrated prior to weighing and you should check with Weights and Measures if you can perform the calibration by purchasing your own optional calibration weight, if you have to hire a local licensed scale technician to perform the calibration or if the Weights and Measures Inspector will calibrate the scale when they inspect it and put the scale into service. You'll need to research this on your own and in some states it can cost you over $150 just for the inspection. Typically they will also place a State W&M Seal on the balance with an expiration date since scales typically they have to be verified and inspected for accuracy yearly.

You will see on the front of the balance above the display a label denoting the model number. This is where so much confusion occurs. The model is shown as FX-300i, then a circle with II inside of the circle meaning this is a Class 2 weighing device, CC 08-045 and the wording "The counting feature is not legal for trade". But wait I thought I ordered the FX-300iN yet the balance is labeled FX-300i.

What has happened is AND Weighing converts the FX-300i into the FX-300iN by changing the balance's internal software so it complies with NTEP requirements. Part of this is so the calibration can be locked out also so the last decimal place on the display is "boxed". They also place the sticker above the display identifying the CofC number and supply the two sealing screws & sealing plate. All these changes and A&D markets the product as the FX-300iN and charges more money.

Many marijuana dispensaries either already have a FX-iN balance and want to expand and order another balance or they visited a dispensary so they can figure out the equipment they need to start a store. Although looking at the digital balance's label is marked either FX-300i for Oregon or for dispensaries in Colorado FX-1200i you need to make sure you order the FX-300iN or FX-1200iN.

 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.

Hot Buys!

Community Poll

What is your favorite balance ?
 
 
 
 
 
 
 
 
  Loading...
Featured Laboratory Balances:
600 g x 0.01 g $259.77
60 g x 0.1 mg $999.51