Digtal scales from Sartorius, Mettler, Ohaus, AND Weighing, Myweigh & more

digital scale lab balances

Scaleman.com is your source for
balances & scales at discount prices
Since 1995!

Skip to Main Content »

Stat-Pen consists of a neutralizing probe that is connected to a power supply unit. The power supply unit has an On/Off switch on the top. When the switch is on, the power supply unit is in the standby mode. In addition, two red LEDs light up when the power is on. The probe itself looks like a pen that you hold in your hand. Point the probe toward the object on which you want to neutralize static electricity, and press the microswitch on the probe to activate it. You should hold the probe preferably at a distance of 30 – 50 mm from the object before you activate the microswitch. When the probe is activated, it starts neutralizing at once. You can also see that it is activated just by looking at the two LEDs. When the probe is activated, the LEDs are brighter. As soon as you release the microswitch on the probe, the power supply unit returns to the standby mode and the probe is discharged automatically. When the probe is not in use, it should be kept in the holder on the side of the power supply unit. The graph shows the speed of neutralization as a function of the distance of the probe from an object. The time given in seconds is the time it takes Stat-Pen to reduce the charge on the object to be weighed from 1,000 volts to 100 volts.Move your mouse over image or click to enlarge

Sartorius YSTP01 Stat Pen

Sartorius
See other products by Sartorius

Availability: Call for availability

MSRP: $1,800.00

YOU PAY: $1,575.00

You save $225.00

Useful Downloads
Manual
Add Items to Cart
OR

Quick Overview

Sartorius stat pen neutralizes static electricity on samples.

Product Description

Stat-Pen consists of a neutralizing probe that is connected to a power supply unit. The power supply unit has an On/Off switch on the top. When the switch is on, the power supply unit is in the standby mode. In addition, two red LEDs light up when the power is on. The probe itself looks like a pen that you hold in your hand.

Point the probe toward the object on which you want to neutralize static electricity, and press the microswitch on the probe to activate it. You should hold the probe preferably at a distance of 30 – 50 mm from the object before you activate the microswitch. When the probe is activated, it starts neutralizing at once. You can also see that it is activated just by looking at the two LEDs. When the probe is activated, the LEDs are brighter. As soon as you release the microswitch on the probe, the power supply unit returns to the standby mode and the probe is discharged automatically. When the probe is not in use, it should be kept in the holder on the side of the power supply unit. The graph shows the speed of neutralization as a function of the distance of the probe from an object. The time given in seconds is the time it takes Stat-Pen to reduce the charge on the object to be weighed from 1,000 volts to 100 volts.

 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.

Hot Buys!

Community Poll

What is your favorite balance ?
 
 
 
 
 
 
 
 
  Loading...
Featured Laboratory Balances:
600 g x 0.01 g $325.77
60 g x 0.1 mg $999.51